Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
J Arthroplasty ; 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38350518

RESUMO

BACKGROUND: Vitamin E-doped cross-linked polyethylene (VEPE) has encouraged the use of larger heads in thinner liners in total hip arthroplasty (THA). However, there are concerns about wear and mechanical failure of the thin liner, especially when metal heads are used. The aim of this randomized controlled trial was to investigate if the use of a large metal head in thin VEPE liner would increase polyethylene wear compared with a standard 32-mm metal head and to compare periacetabular radiolucencies and patient-reported outcomes in THA. METHODS: There were 96 candidates for uncemented THA who were randomly allocated to either the largest possible metal head (36 to 44 mm) that could be fitted in the thinnest available VEPE liner (intervention group) or a standard 32-mm metal head (control group). The primary outcome was proximal head penetration, measured with a model-based radiostereometric analysis. Secondary outcomes were periacetabular radiolucencies and patient-reported outcomes. The midterm results of the trial at 5 years are presented. RESULTS: The median total proximal head penetration (interquartile range) was -0.04 mm (-0.12 to 0.02) in the intervention group and -0.03 mm (-0.14 to 0.05) in the control group (P = .691). The rates of periacetabular radiolucencies were 1 of 44 and 4 of 42 (P = .197), respectively. Patient-reported hip function and health-related quality of life did not differ between the groups, but participants in the intervention group reported a higher level of activity (median University of California Level of Activity score 7 versus 6, P = .020). There were 5 revisions caused by dislocations (2), periprosthetic fracture (1), stem subsidence (1), or iliopsoas impingement (1). CONCLUSIONS: Large metal heads in thin VEPE liners did not increase liner wear and were not associated with liner failure 5 years after THA.

2.
BMC Musculoskelet Disord ; 25(1): 117, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336666

RESUMO

BACKGROUND: Hip dysplasia is a condition where the acetabulum is too shallow to support the femoral head and is commonly considered a risk factor for hip osteoarthritis. The objective of this study was to develop a deep learning model to diagnose hip dysplasia from plain radiographs and classify dysplastic hips based on their severity. METHODS: We collected pelvic radiographs of 571 patients from two single-center cohorts and one multicenter cohort. The radiographs were split in half to create hip radiographs (n = 1022). One orthopaedic surgeon and one resident assessed the radiographs for hip dysplasia on either side. We used the center edge (CE) angle as the primary diagnostic criteria. Hips with a CE angle < 20°, 20° to 25°, and > 25° were labeled as dysplastic, borderline, and normal, respectively. The dysplastic hips were also classified with both Crowe and Hartofilakidis classification of dysplasia. The dataset was divided into train, validation, and test subsets using 80:10:10 split-ratio that were used to train two deep learning models to classify images into normal, borderline and (1) Crowe grade 1-4 or (2) Hartofilakidis grade 1-3. A pre-trained on Imagenet VGG16 convolutional neural network (CNN) was utilized by performing layer-wise fine-turning. RESULTS: Both models struggled with distinguishing between normal and borderline hips. However, achieved high accuracy (Model 1: 92.2% and Model 2: 83.3%) in distinguishing between normal/borderline vs. dysplastic hips. The overall accuracy of Model 1 was 68% and for Model 2 73.5%. Most misclassifications for the Crowe and Hartofilakidis classifications were +/- 1 class from the correct class. CONCLUSIONS: This pilot study shows promising results that a deep learning model distinguish between normal and dysplastic hips with high accuracy. Future research and external validation are warranted regarding the ability of deep learning models to perform complex tasks such as identifying and classifying disorders using plain radiographs. LEVEL OF EVIDENCE: Diagnostic level IV.


Assuntos
Aprendizado Profundo , Luxação Congênita de Quadril , Luxação do Quadril , Humanos , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/cirurgia , Projetos Piloto , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Radiografia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Estudos Retrospectivos
3.
Bone Joint J ; 106-B(3 Supple A): 31-37, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423094

RESUMO

Aims: In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients. Methods: A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively. Results: At five years, the median levels of chromium, cobalt, and titanium were 0.5 µg/l (interquartile range (IQR) 0.50 to 0.62), 0.24 µg/l (IQR 0.18 to 0.30), and 1.16 µg/l (IQR 1.0 to 1.68) for the 32 mm group, and 0.5 µg/l (IQR 0.5 to 0.54), 0.23 µg/l (IQR 0.17 to 0.39), and 1.30 µg/l (IQR 1 to 2.05) for the 36 mm to 44 mm group, with no significant difference between the groups (p = 0.825, p = 1.000, p = 0.558). There were increased levels of metal ions at two years postoperatively in seven patients in the 32 mm group, compared with four in the 36 mm to 44 mm group, and at five years postoperatively in six patients in the 32 mm group, compared with seven in the 36 mm to 44 mm group. There was no significant difference in either the OHS (p = 0.665) or UCLA (p = 0.831) scores between patients with or without an increased level of metal ions. Conclusion: In patients who underwent MoP THA, we found no differences in the levels of metal ions five years postoperatively between those with a femoral head of 32 mm and those with a femoral head of between 36 mm and 44 mm, and no corrosion-related revisions. As taper corrosion can start after five years, there remains a need for longer-term studies investigating the relationship between the size of the femoral head size and corrosion in patients undergoing MoP THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Íons , Metais , Polietileno
4.
J Arthroplasty ; 39(3): 683-688, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37625465

RESUMO

BACKGROUND: Over the past couple of decades, the definition of success after total knee arthroplasty (TKA) has shifted away from clinician-rated metrics and toward the patient's subjective experience. Therefore, understanding the aspects of patient recovery that drive 3-year to 5-year satisfaction after TKA is crucial. The aims of this study were to (1) determine the 1-year postoperative factors, specifically patient-reported outcome measures (PROMs) that were associated with 3-year and 5-year postoperative satisfaction and (2) understand the factors that drive those who are not satisfied at 1 year postoperatively to become satisfied later in the postoperative course. METHODS: This was a retrospective study of 402 TKA patients who were gathered prospectively and presented for their 1-year follow-up. Demographics were collected preoperatively and patient-reported outcomes were collected at 1, 3, and 5 years postoperatively. Logistic regressions were used to identify the factors at 1 year that were associated with 3-year and 5-year satisfaction. RESULTS: Associations between 1-year PROMs with 3-year satisfaction were observed. Longer term satisfaction at 5 years was more closely associated with EuroQol 5 Dimension Mobility, Activity Score, and Numerical Rating Scale Satisfaction. Of those who were not satisfied at 1 year, EuroQol 5 Dimension Mobility, Knee Disability Osteoarthritis Outcome Score Function in Sport and Recreation, and Satisfaction were associated with becoming satisfied at 3 years. CONCLUSION: The 1-year PROMs were found to be associated with satisfaction at 3 to 5 years after TKA. Importantly, many of the PROMs that were associated with 3-year to 5-year satisfaction, especially in those who were not originally satisfied at 1 year, were focused on mobility and activity level.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Satisfação do Paciente , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento , Articulação do Joelho/cirurgia
5.
Bone Rep ; 19: 101723, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38047271

RESUMO

Introduction: Osseointegration of hip implants, although a decade-long process, shows striking similarities with the four major phases of endochondral bone repair. In the current study we investigated the spatiotemporal involvement of bone morphogenic proteins (BMPs) and transforming growth factor betas (TGF-ßs) throughout the process of bone repair leading to successfully osseointegrated hip implants. Materials and methods: Twenty-four patients that had undergone primary total hip arthroplasty (THA) due to one-sided osteoarthritis (OA) were investigated during a period of 18 years (Y) with repeated measurements of plasma biomarkers as well as clinical and radiological variables. All implants were clinically and radiographically well anchored throughout the follow-up. Eighty-one healthy donors divided in three gender- and age-matched groups and twenty OA patients awaiting THA, served as controls. Plasma was analyzed for BMP-1, -2, -3, -4, -6, -7 -9 and TGF-ß1, -ß2, -ß3 by use of a high-sensitivity and wide dynamic range electrochemiluminescence technique allowing for detection of minor changes. Results: Spatiotemporal changes during the follow-up are presented in the context of the four phases of endochondral bone repair shown in earlier studies and transposed to the current study based on similarities in biomarker responses. Phase 1: Primary proinflammatory phase lasting from surgery until day 7, Phase 2: Chondrogenic phase from day 7 until 18 months postsurgery, Phase 3: Secondary proinflammatory and cartilage remodeling phase lasting from 18 months until 7Y, Phase 4: coupled bone remodeling from 7Y until 18Y postsurgery. BMP-1 increased sharply shortly after surgery and remained significantly above healthy during the chondrocyte recruitment, proliferation, and hypertrophy phases with a subsequent return to control level at 5Y postsurgery. BMP-2 was above healthy controls before surgery and 1 day after surgery before decreasing to control level and remaining there throughout the follow-up. BMP-3 was at control level from presurgery until 6M after surgery when it increased to a peak at 2Y during the cartilage hypertrophy phase followed by a gradual decrease to control level at 10Y during the phase of bone formation. In the following, BMP-3 decreased below controls to a nadir 15Y postsurgery during coupled bone remodeling. BMP-4 was at control level from presurgery until 10Y postsurgery when it increased to a sharp peak at 15Y after surgery followed by a return to the level of healthy at 18Y. BMP-6 did not differ from healthy during the follow-up. BMP-7 was at control level from presurgery until 1Y postsurgery before gradually increasing to a peak at 10Y during the early phase of osteogenesis with a gradual return to control level at 18Y during the phase of coupled bone remodeling. BMP-9 was above OA before surgery followed by a decrease to basal level on day 1 after surgery and a renewed increase to a plateau above controls lasting from 6 W until returning to the level of healthy at 18Y postsurgery, i.e., throughout the phases of cartilage formation, cartilage hypertrophy and remodeling, bone formation and coupled bone remodeling. TGF-ß1 was above controls presurgery before decreasing to baseline shortly after surgery followed by a renewed increase at 6 M to a peak at 2Y during cartilage hypertrophy/remodeling followed by a gradual return to baseline at 10Y during early osteoblastogenesis. TGF-ß2 was at control level from presurgery until the phase of cartilage remodeling at 5Y when it increased sharply to a peak at 7Y with a gradual return to baseline at 18Y postsurgery. TGF-ß3 remained at control level throughout the study. Conclusion: This study shows that the involvement of BMPs and TGF-ßs in endochondral bone repair is a process of stepwise recruitment of individual biomarkers characterized by distinct, yet overlaping, spatiotemporal patterns that extend from the early phase of pre-chondrocyte recruitment until the late phase of coupled bone remodeling.

6.
Hip Int ; 33(2): 184-192, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34102902

RESUMO

AIM: To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. METHODS: In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36-44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. RESULTS: At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08-0.15) versus 0.12 µg/L (0.08-0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50-0.59) versus 0.50 µg/L (0.50-1.20), p = 0.059, for chromium and 1.58 µg/L (1.38-2.05) versus 1.48 µg/L (1.14-1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12-0.24) versus 0.18 µg/L (0.12-0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50-0.50) versus 0.50 µg/L (0.50-0.57), p = 0.554, for chromium and 1.54 µg/L (1.16-1.87) versus 1.42 µg/L (1.01-1.72), p = 0.207 for titanium. CONCLUSIONS: The use of the largest possible metal head (36-44 mm) compared to a 32-mm head in metal-on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels.Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704).


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Titânio , Polietileno , Metais , Cromo , Cobalto , Íons , Desenho de Prótese
7.
Antimicrob Resist Infect Control ; 11(1): 113, 2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-36064457

RESUMO

BACKGROUND: Surgical site infection (SSI) after acute hip fracture surgery is a devastating complication associated with increased suffering and mortality. The aim of the study was to investigate early SSI, sepsis, pneumonia and urinary tract infections over five years, before and after the implementation of the Safe Hands project. METHODS: This was a single-centre observational study with a 5-year longitudinal design, investigating the effects of an infection-prevention intervention targeting the clinical care pathway of individuals with acute hip fracture. Statistical analyses were based on routinely collected patient outcome data comprising 3553 patients. The study conforms to the criteria of the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE). RESULTS: The incidence of early SSIs decreased from 2.5% in years 1-2 to 1.1% in years 4-5. Similar results were observed for sepsis (2.7% to 1.3%) and urinary tract infections (14.2% to 4.2%). The multivariable regression results suggest that, for every observed year, the odds of early SSIs decreased. Male gender, procedure time, sepsis and preoperative skin damage increased the odds significantly. CONCLUSIONS: Our preventive bundle, based on partnership between researchers, managers and clinicians and a strong commitment to change from the involved professions, appear to be effective in reducing the frequency of potentially devastating SSIs and other hospital acquired infections after hip fracture surgery. The use of external and internal facilitators was crucial to enable individual and organisational learning and overcoming barriers to improvements. TRIAL REGISTRATION: Clinical Trials.gov ID: NCT02983136 Registered 6 December 2016-Retrospectively registered.


Assuntos
Fraturas do Quadril , Sepse , Infecções Urinárias , Fraturas do Quadril/complicações , Fraturas do Quadril/cirurgia , Humanos , Masculino , Sepse/epidemiologia , Sepse/prevenção & controle , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Infecções Urinárias/epidemiologia , Infecções Urinárias/prevenção & controle
8.
BMJ Open ; 12(7): e061077, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35835527

RESUMO

OBJECTIVE: To evaluate the effects of competition and a bundled payment model on the performance of hip replacement surgery. DESIGN: A quasi-experimental study where a difference-in-differences analytical framework is applied to analyse routinely collected patient-level data from multiple registers. SETTING: Hospitals providing hip replacement surgery in Sweden. PARTICIPANTS: The study included patients who underwent elective primary total hip replacement due to osteoarthritis from 2005 to 2012. The final study sample consisted of 85 275 hip replacement surgeries, where the exposure group consisted of 14 570 surgeries (n=6380 prereform and n=8190 postreform) and the control group consisted of 70 705 surgeries (n=32 799 prereform and n=37 906 postreform). INTERVENTION: A reform involving patient choice, free entry of new providers and a bundled payment model for hip replacement surgery, which came into force in 2009 in Region Stockholm, Sweden. OUTCOME MEASURES: Performance is measured as length of stay of the surgical admission, adverse event rate within 90 days following surgery and patient satisfaction 1 year postsurgery. RESULTS: The reform successfully improved the adverse event rate (1.6 percentage reduction, p<0.05). Length of stay decreased less in the more competitive market than in the control group (0.7 days lower, p<0.01). These effects were mainly driven by university and central hospitals. No effects of the reform on patient satisfaction were found (no significance). CONCLUSIONS: The study concludes that the incentives of the reform focusing on avoidance of adverse events have a predictable impact. Since the payment for providers is fixed per case, the impact on resource use is limited. Our findings contribute to the general knowledge about the effects of financial incentives and market-oriented reforms.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Hospitais , Humanos , Suécia , Estados Unidos
10.
Infect Prev Pract ; 4(3): 100222, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35722048

RESUMO

Background: Airborne bacteria present in the operating room may be a cause of surgical site infection, either contaminating the surgical wound directly, or indirectly via e.g. surgical instruments. The aim of this study was to evaluate if instrument and assistant tables equipped with local unidirectional airflow reduce bacterial contamination of the instrument area to ultra clean levels, during orthopedic implant surgery in an operating room with displacement ventilation. Methods: Local airflow units of instrument and assistant tables were either active or inactive. Colony forming units were sampled intraoperatively from the air above the instruments and from instrument dummies. A minimum of three air samples and two-three samples from instrument dummies were taken during each surgery. Samples were incubated on agar for total aerobic bacterial count. The mean air and instrument contamination during each surgery was calculated and used to analyze the difference in contamination depending on use of local airflow or not. All procedures were performed in the same OR. Results: 188 air and 124 instrument samples were collected during 48 orthopedic implant procedures. Analysis showed that local unidirectional airflow above the surgical instruments significantly reduced the bacterial count in the air above assistant table (P<0.001) and instrument table (P=0.002), as well as on the instrument dummies from the assistant table (P=0.001). Conclusions: Instrumentation tables equipped with local unidirectional airflow protect the surgical instruments from bacterial contamination during orthopedic implant surgery and may therefore reduce the risk of indirect wound contamination.

11.
Hip Int ; 32(1): 56-61, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33167730

RESUMO

BACKGROUND: Introduction of new implants should be monitored closely to capture any signs of compromising patient safety. Vitamin E infused highly-crosslinked polyethylene liners (VEPE) offer the potential for reduced wear. Highwall liners have been hypothesised to result in increased wear and potential liner fractures. The aim of this study was to determine the 3-7-year follow-up of highwall VEPE for primary total hip arthroplasty (THA), focusing on liner-related complications. METHODS: We included 1221 consecutive THA operations from July 2010 to May 2014 with minimum follow-up of 3 (3.1-6.8) years Data collected included demographics, implant data, complications, reoperations, and deaths. Data were cross-referenced with the Danish Hip Arthroplasty Registry in order to ensure validity and completeness. Acetabular shell position was measured using Martell Hip Analysis Suite in a subgroup of 931 THAs. RESULTS: Cumulative stem revision and shell revision at 3-year follow-up was 3.4% and 0.4% respectively. There were no revisions due to liner failure. Reason for revision included 11 dislocations, 15 soft-tissue revisions for infection, 44 stem revisions of which 34 were periprosthetic fractures and 13 shell revisions of which 6 were combined shell and stem revisions. CONCLUSION: Early follow-up of VEPE liners for primary THA have not shown any revisions associated with liner failure. Continued monitoring of new materials are necessary to capture any signs of compromised patient safety.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Vitamina E
12.
SICOT J ; 7: 61, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34851264

RESUMO

Total hip arthroplasty (THA) has been quoted as "the operation of the century", owing to its efficacy and the substantial improvements evidenced with respect to functional patient outcomes and quality of life. However, early postoperative complications are often inevitable, hence it is imperative to take every step to prevent them and minimise morbidity and mortality. This manuscript focuses on the most common early complications following THA, namely venous thromboembolism (VTE), prosthetic joint infection, periprosthetic fracture, instability, and leg length inequality. It aims to outline effective risk stratification strategies and prevention measures that could apply to the wider Orthopaedic community.

13.
J Orthop Translat ; 30: 31-40, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34485075

RESUMO

BACKGROUND: Periprosthetic joint infections (PJI) are challenging complications following arthroplasty. Staphylococci are a frequent cause of PJI and known biofilm producers. Biofilm formation decreases antimicrobial susceptibility, thereby challenging favourable treatment outcomes. The aims of this study were to characterize the biofilm abilities and antimicrobial susceptibilities of staphylococci causing first-time PJI and correlate them to clinical outcome (infection resolution and recurrence). METHODS: Reoperations for PJI of the hip or knee between 1st January 2012 to 30th June 2015 performed at the Sahlgrenska University Hospital were identified in a local database. Medical records were reviewed and clinical parameters recorded for patients whose intraoperative bacterial isolates had been stored at the clinical laboratory. Staphylococcal strains isolated from reoperations due to first-time PJI were characterised by their ability to form biofilms using the microtiter plate test. Antimicrobial susceptibility of the strains was determined by minimum inhibitory concentration (MIC) when grown planktonically, and by minimum biofilm eradication concentration (MBEC) when grown as biofilms. MBEC determination was conducted using the Calgary biofilm device (CBD) and a custom-made antimicrobial susceptibility plate containing eight clinically relevant antimicrobial agents. RESULTS: The study group included 49 patients (70 bacterial strains) from first-time PJI, whereof 24 (49%) patients had recurrent infection. Strong biofilm production was significantly associated with recurrent infection. Patients infected with strong biofilm producers had a five-fold increased risk for recurrent infection. Strains grown as biofilms were over 8000 times more resistant to antimicrobial agents compared to planktonic cultures. Biofilms were more susceptible to rifampicin compared to other antimicrobials in the assay. Increased biofilm susceptibility (MBEC â€‹> â€‹MIC) was observed for the majority of the bacterial strains and antimicrobial agents. CONCLUSIONS: Strong biofilm production was significantly associated with increased antimicrobial resistance and PJI recurrence. This underscores the importance of determining biofilm production and susceptibility as part of routine diagnostics in PJI. Strong staphylococcal biofilm production may have implications on therapeutic choices and suggest more extensive surgery. Furthermore, despite the increased biofilm resistance to rifampicin, results from this study support its use in staphylococcal PJI. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Like for many biomaterial-associated infections, staphylococci are a common cause of PJI. Their ability to adhere to surfaces and produce biofilms on medical devices is proposed to play a role. However, clinical studies where biofilm properties are directly linked to patient outcome are scarce. This study demonstrates that the majority of staphylococci isolated from first-time PJI were biofilm producers with increased antimicrobial resistance. Patients suffering an infection caused by a staphylococcal strain with strong biofilm production ability had a five-fold greater risk of recurrent infection. This novel finding suggests the importance of evaluating biofilm production as a diagnostic procedure for the guidance of treatment decisions in PJI.

14.
Lancet Digit Health ; 3(8): e471-e485, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34215564

RESUMO

BACKGROUND: Early detection of postoperative complications, including organ failure, is pivotal in the initiation of targeted treatment strategies aimed at attenuating organ damage. In an era of increasing health-care costs and limited financial resources, identifying surgical patients at a high risk of postoperative complications and providing personalised precision medicine-based treatment strategies provides an obvious pathway for reducing patient morbidity and mortality. We aimed to leverage deep learning to create, through training on structured electronic health-care data, a multilabel deep neural network to predict surgical postoperative complications that would outperform available models in surgical risk prediction. METHODS: In this retrospective study, we used data on 58 input features, including demographics, laboratory values, and 30-day postoperative complications, from the American College of Surgeons (ACS) National Surgical Quality Improvement Program database, which collects data from 722 hospitals from around 15 countries. We queried the entire adult (≥18 years) database for patients who had surgery between Jan 1, 2012, and Dec 31, 2018. We then identified all patients who were treated at a large midwestern US academic medical centre, excluded them from the base dataset, and reserved this independent group for final model testing. We then randomly created a training set and a validation set from the remaining cases. We developed three deep neural network models with increasing numbers of input variables and so increasing levels of complexity. Output variables comprised mortality and 18 different postoperative complications. Overall morbidity was defined as any of 16 postoperative complications. Model performance was evaluated on the test set using the area under the receiver operating characteristic curve (AUC) and compared with previous metrics from the ACS-Surgical Risk Calculator (ACS-SRC). We evaluated resistance to changes in the underlying patient population on a subset of the test set, comprising only patients who had emergency surgery. Results were also compared with the Predictive OpTimal Trees in Emergency Surgery Risk (POTTER) calculator. FINDINGS: 5 881 881 surgical patients, with 2941 unique Current Procedural Terminology codes, were included in this study, with 4 694 488 in the training set, 1 173 622 in the validation set, and 13 771 in the test set. The mean AUCs for the validation set were 0·864 (SD 0·053) for model 1, 0·871 (0·055) for model 2, and 0·882 (0·053) for model 3. The mean AUCs for the test set were 0·859 (SD 0·063) for model 1, 0·863 (0·064) for model 2, and 0·874 (0·061) for model 3. The mean AUCs of each model outperformed previously published performance metrics from the ACS-SRC, with a direct correlation between increasing model complexity and performance. Additionally, when tested on a subgroup of patients who had emergency surgery, our models outperformed previously published POTTER metrics. INTERPRETATION: We have developed unified prediction models, based on deep neural networks, for predicting surgical postoperative complications. The models were generally superior to previously published surgical risk prediction tools and appeared robust to changes in the underlying patient population. Deep learning could offer superior approaches to surgical risk prediction in clinical practice. FUNDING: The Novo Nordisk Foundation.


Assuntos
Análise de Dados , Modelos Biológicos , Redes Neurais de Computação , Complicações Pós-Operatórias , Adolescente , Adulto , Idoso , Área Sob a Curva , Tecnologia Biomédica , Gerenciamento de Dados , Bases de Dados Factuais , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
15.
Bone Joint J ; 103-B(7): 1206-1214, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34192938

RESUMO

AIMS: We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty. METHODS: In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes. RESULTS: At two years, 44 patients in each group were available for RSA assessment. The median total two-year proximal head penetration was -0.02 mm (IQR -0.09 to 0.07; p = 0.548) for the largest possible head and -0.01 mm (IQR -0.07 to 0.10; p = 0.525) for 32 mm heads. Their difference was not statistically significant (p = 0.323). Neither group demonstrated a bedding-in period. The median steady-state volumetric wear rates were 6.1 mm3/year (IQR -59 to 57) and 3.5 mm3/year (-21 to 34) respectively, and did not differ between the groups (p = 0.848). There were no statistically significant differences in periacetabular radiolucencies or patient-reported outcomes. CONCLUSION: The use of the largest possible metal head did not increase vitamin E-doped cross-linked polyethylene wear compared with 32 mm heads at two years. Linear wear was negligible and volumetric wear rates were very low in both head size groups. There was a tendency towards higher values of volumetric wear in large heads that warrants longer-term evaluation before any definite conclusions about the association between head size and wear can be drawn. Cite this article: Bone Joint J 2021;103-B(7):1206-1214.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Polietileno/química , Vitamina E/administração & dosagem , Idoso , Ligas de Cromo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Porosidade , Desenho de Prótese , Falha de Prótese , Análise Radioestereométrica , Método Simples-Cego , Propriedades de Superfície
17.
BMC Health Serv Res ; 21(1): 387, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33902580

RESUMO

BACKGROUND: Competition-promoting reforms and economic incentives are increasingly being introduced worldwide to improve the performance of healthcare delivery. This study considers such a reform which was initiated in 2009 for elective hip replacement surgery in Stockholm, Sweden. The reform involved patient choice of provider, free establishment of new providers and a bundled payment model. The study aimed to examine its effects on hip replacement surgery quality as captured by patient reported outcome measures (PROMs) of health gain (as indicated by the EQ-5D index and a visual analogue scale (VAS)), pain reduction (VAS) and patient satisfaction (VAS) one and six years after the surgery. METHODS: Using patient-level data collected from multiple national registers, we applied a quasi-experimental research design. Data were collected for elective primary total hip replacements that were carried out between 2008 and 2012, and contain information on patient demography, the surgery and PROMs at baseline and at one- and six-years follow-up. In total, 36,627 observations were included in the analysis. First, entropy balancing was applied in order to reduce differences in observable characteristics between treatment groups. Second, difference-in-difference analyses were conducted to eliminate unobserved time-invariant differences between treatment groups and to estimate the causal treatment effects. RESULTS: The entropy balancing was successful in creating balance in all covariates between treatment groups. No significant effects of the reform were found on any of the included PROMs at one- and six-years follow-up. The sensitivity analyses showed that the results were robust. CONCLUSIONS: Competition and bundled payment had no effects on the quality of hip replacement surgery as captured by post-surgery PROMs of health gain, pain reduction and patient satisfaction. The study provides important insights to the limited knowledge on the effects of competition and economic incentives on PROMs.


Assuntos
Artroplastia de Quadril , Humanos , Medição da Dor , Medidas de Resultados Relatados pelo Paciente , Suécia , Resultado do Tratamento , Escala Visual Analógica
18.
Arthroplast Today ; 7: 29-36, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33521194

RESUMO

BACKGROUND: Total hip arthroplasty (THA) performed on patients with Perthes-like deformities are technically challenging because of the patient's abnormal hip anatomy. Patients with Perthes-like deformities are at a higher risk of revision, aseptic loosening, nerve injury, and intraoperative fracture after THA, especially if shortening osteotomies are performed. This analysis sought to examine the clinical and radiographic outcomes of a patient cohort with Perthes-like deformities receiving THA with a conical stem, an elevated hip center, and no shortening femoral osteotomy. METHODS: Twenty-six patients (27 hips) received THA with MODULUS femoral stems, ceramic or metal femoral heads, and highly cross-linked polyethylene liners between April 2011 and March 2016. All patients were treated at a single center by 4 participating surgeons. Patients completed 2 questionnaires preoperatively and at the final follow-up visit (between 1 and 5 years postoperatively): Harris Hip Score and Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire. Differences in patient-reported outcome measures (PROM) scores were measured by paired t-tests. Preoperative and postoperative anteroposterior radiographs were analyzed to monitor patient outcomes. RESULTS: Significant clinical improvements were observed in all individual subcategories of the Harris Hip Score and of the Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire; the largest magnitude improvements were observed in the subcategory of pain relief for both questionnaires. No complications, including intraoperative and postoperative femoral fractures, nerve palsy, dislocations, or deep venous thrombosis, were observed. CONCLUSION: This study found that patients treated with an elevated hip center and low stem-positioning technique using a conical, modular implant system had good clinical outcomes and did not suffer complications at the mean follow-up from surgery of 2.8 years (range: 1-5 years).

19.
Comput Biol Med ; 129: 104140, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33278631

RESUMO

BACKGROUND: Accurate and timely detection of medical adverse events (AEs) from free-text medical narratives can be challenging. Natural language processing (NLP) with deep learning has already shown great potential for analyzing free-text data, but its application for medical AE detection has been limited. METHOD: In this study, we developed deep learning based NLP (DL-NLP) models for efficient and accurate hip dislocation AE detection following primary total hip replacement from standard (radiology notes) and non-standard (follow-up telephone notes) free-text medical narratives. We benchmarked these proposed models with traditional machine learning based NLP (ML-NLP) models, and also assessed the accuracy of International Classification of Diseases (ICD) and Current Procedural Terminology (CPT) codes in capturing these hip dislocation AEs in a multi-center orthopaedic registry. RESULTS: All DL-NLP models outperformed all of the ML-NLP models, with a convolutional neural network (CNN) model achieving the best overall performance (Kappa = 0.97 for radiology notes, and Kappa = 1.00 for follow-up telephone notes). On the other hand, the ICD/CPT codes of the patients who sustained a hip dislocation AE were only 75.24% accurate. CONCLUSIONS: We demonstrated that a DL-NLP model can be used in largescale orthopaedic registries for accurate and efficient detection of hip dislocation AEs. The NLP model in this study was developed with data from the most frequently used electronic medical record (EMR) system in the U.S., Epic. This NLP model could potentially be implemented in other Epic-based EMR systems to improve AE detection, and consequently, quality of care and patient outcomes.


Assuntos
Artroplastia de Quadril , Aprendizado Profundo , Artroplastia de Quadril/efeitos adversos , Registros Eletrônicos de Saúde , Humanos , Aprendizado de Máquina , Processamento de Linguagem Natural , Redes Neurais de Computação
20.
Hip Int ; 31(3): 378-387, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-31746236

RESUMO

INTRODUCTION: Our first aim was to report the longitudinal clinical performance of patients treated with the ASR Hip System, a metal-on-metal (MoM) device, in their mid- to late-term follow-up. Secondly, we sought to report on the reasons and risk factors for mid- to late-term implant failure. METHODS: A total of 1721 ASR patients (1933 hips) from 16 centres in 6 countries were enrolled to a prospective, post-recall study. The average time to enrollment was 7.4 years from index surgery. Data from 3 follow-up visits over 2 years were analysed. Implant performance, based on ion levels and PROMs, was determined at each clinical visit. RESULTS: The proportion of those exhibiting good performance decreased over time for hip resurfacing (ASR HRA) and total hip arthroplasty (ASR XL) patients. ASR XL patients were likely to exhibit longitudinal blood metal ion increases regardless of symptom state. ASR HRA patients were more likely to present with and maintain good performance over time, especially males with high general health indicators. 6% of ASR HRA and 14% of ASR XL patients were revised throughout the study period. DISCUSSION: ASR XL THA patients are likely to exhibit blood metal ion increases without accompanying changes in symptom state, and therefore should be followed with annual blood tests at minimum. While appropriately selected ASR HRA patients were the most likely to exhibit low blood metal ion levels and report no symptoms, we recommend vigilant follow-up of all ASR patients to ensure that worsening clinical outcomes and asymptomatic soft tissue damage are not missed.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA